- Home
- Enterprise
- High Density Servers
- H281-PE0
H281-PE0 (rev. 100/200)
HCI Server – Intel DP 2U 4 Nodes Server
| Application:
HCI
&
Hybrid/Private Cloud Server
Application:
- Supports 5G network infrastructure
- 2U - 4 nodes with front access to the node trays
- 2nd Gen. Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
- 8 x LGA 3647 sockets
- Intel® C621 Express Chipset
- 6-Channel RDIMM/LRDIMM DDR4, 96 x DIMMs
- Supports Intel® Optane™ DC Persistent Memory
- 8 x 10Gb/s BASE-T LAN ports (Intel® X550-BT2)
- 1 x CMC global management port
- 8 x 2.5" SAS/SATA hot-swappable HDD/SSD bays
- Ultra-Fast M.2 with PCIe Gen3 x4 interface
- 4 x front side and 8 x rear side low profile PCIe Gen3 x16 expansion slots
- 4 x OCP Gen3 mezzanine slots
- Aspeed® AST2500 remote management controller
- 2200W 80 PLUS Platinum redundant PSU
- Optimized performance with Mellanox Infiniband EDR 100G or Ethernet 100G products
Request a Quote
* The entire materials provided herein are for reference only. GIGABYTE reserves the right to modify or revise the content at anytime without prior notice.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.
SPECIFICATIONS
Dimensions (WxHxD, mm)
2U 4 Nodes - Front access
447 x 87 x 902.3
447 x 87 x 902.3
Motherboard
MH81-LM0
CPU
2nd Generation Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor
CPU TDP up to 165W
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor
CPU TDP up to 165W
NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable
Socket
Per Node:
2 x LGA 3647
Total:
8 x LGA 3647
Socket P
2 x LGA 3647
Total:
8 x LGA 3647
Socket P
Chipset
Intel® C621 Express Chipset
Memory
Per node:
24 x DIMM slots
Total:
96 x DIMM slots
DDR4 memory supported only
6-channel memory architecture
RDIMM modules up to 64GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz
NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only
24 x DIMM slots
Total:
96 x DIMM slots
DDR4 memory supported only
6-channel memory architecture
RDIMM modules up to 64GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz
NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only
LAN
Per node:
2 x 10Gb/s BASE-T LAN ports (Intel® X550-BT2)
1 x Dedicated management port
Total:
8 x 10Gb/s BASE-T LAN ports (Intel® X550-BT2)
4 x Dedicated management ports
1 x 10/100/1000 *CMC global management port
*CMC: Chassis Management Controller, to monitor all status of computing nodes.
2 x 10Gb/s BASE-T LAN ports (Intel® X550-BT2)
1 x Dedicated management port
Total:
8 x 10Gb/s BASE-T LAN ports (Intel® X550-BT2)
4 x Dedicated management ports
1 x 10/100/1000 *CMC global management port
*CMC: Chassis Management Controller, to monitor all status of computing nodes.
Video
Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Management chip in CMC board:
Integrated in Aspeed® AST1250
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Management chip in CMC board:
Integrated in Aspeed® AST1250
Audio
-
Storage
Per node:
2 x 2.5" 7mm SATA/SAS hot-swappable HDD/SSD bays
Total:
8 x 2.5" 7mm SATA/SAS hot-swappable HDD/SSD bays
SAS card is required for SAS devices support
2 x 2.5" 7mm SATA/SAS hot-swappable HDD/SSD bays
Total:
8 x 2.5" 7mm SATA/SAS hot-swappable HDD/SSD bays
SAS card is required for SAS devices support
RAID
Intel® SATA RAID 0/1
Peripheral Drives
-
Expansion Slots
Per node:
- Front side:
1 x Half-length low-profile slot with PCIe x16 (Gen3 x16 bus)
1 x OCP mezzanine slot with PCIe Gen3 x16 bus
- Rear side:
2 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
1 x M.2 slot:
- M-key
- PCIe Gen3 x4
- Supports NGFF-2280 cards
Total:
- Front side:
4 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
4 x OCP mezzanine slots with PCIe Gen3 x16 bus
- Rear side:
8 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
4 x M.2 slots:
- M-key
- PCIe Gen3 x4
- Supports NGFF-2280 cards
- Front side:
1 x Half-length low-profile slot with PCIe x16 (Gen3 x16 bus)
1 x OCP mezzanine slot with PCIe Gen3 x16 bus
- Rear side:
2 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
1 x M.2 slot:
- M-key
- PCIe Gen3 x4
- Supports NGFF-2280 cards
Total:
- Front side:
4 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
4 x OCP mezzanine slots with PCIe Gen3 x16 bus
- Rear side:
8 x Half-length low-profile slots with PCIe x16 (Gen3 x16 bus)
4 x M.2 slots:
- M-key
- PCIe Gen3 x4
- Supports NGFF-2280 cards
Internal I/O
Per node:
4 x SlimSAS connectors
1 x SATA III 6Gb/s port
1 x TPM header
1 x VROC connector
1 x PMBUS header
1 x IPMB connector
1 x Clear CMOS jumper
4 x SlimSAS connectors
1 x SATA III 6Gb/s port
1 x TPM header
1 x VROC connector
1 x PMBUS header
1 x IPMB connector
1 x Clear CMOS jumper
Front I/O
Per node:
2 x USB 3.0
1 x VGA
2 x RJ45
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x Status LED
1 x NMI button
1 x Reset button
Total:
8 x USB 3.0
4 x VGA
8 x RJ45
4 x MLAN
4 x Power button with LED
4 x ID button with LED
4 x Status LED
4 x NMI button
4 x Reset button
2 x USB 3.0
1 x VGA
2 x RJ45
1 x MLAN
1 x Power button with LED
1 x ID button with LED
1 x Status LED
1 x NMI button
1 x Reset button
Total:
8 x USB 3.0
4 x VGA
8 x RJ45
4 x MLAN
4 x Power button with LED
4 x ID button with LED
4 x Status LED
4 x NMI button
4 x Reset button
Rear I/O
CMC module:
1 x MLAN
1 x MLAN Cascade Port
1 x Status LED
1 x Power on LED
Expansion module:
1 x Power on LED
1 x MLAN
1 x MLAN Cascade Port
1 x Status LED
1 x Power on LED
Expansion module:
1 x Power on LED
Backplane I/O
Per node:
2 x SAS/SATA ports
2 x SAS/SATA ports
TPM
1 x TPM header with SPI interface
Optional TPM2.0 kit: CTM010
Optional TPM2.0 kit: CTM010
Power Supply
2 x 2200W redundant PSUs
80 PLUS Platinum
AC Input:
- 100-127V~/ 14A, 47-63Hz
- 200-240V~/ 12.6A, 47-63Hz
DC Output:
- Max 1200W/ 100-127V~
+12.12V/ 95.6A
+12Vsb/ 3.5A
- Max 2200W/ 200-240V
+12.12V/ 178.1A +12Vsb/ 3.5A
NOTE:
* The system power supply requires C19 type power cord
* 2000W 80 PLUS Titanium PSU as an option
+12.12V/ 178.1A +12Vsb/ 3.5A
NOTE:
* The system power supply requires C19 type power cord
* 2000W 80 PLUS Titanium PSU as an option
System Management
Aspeed® AST2500 management controller
Avocent® MergePoint IPMI 2.0 web interface:
Avocent® MergePoint IPMI 2.0 web interface:
- Network settings
- Network security settings
- Hardware information
- Users control
- Services settings
- IPMI settings
- Sessions control
- LDAP settings
- Power control
- Fan profiles
- Voltages, fans and temperatures monitoring
- System event log
- Events management (platform events, trap settings, email settings)
- Serial Over LAN
- vKVM & vMedia (HTML5)
OS Compatibility
For Skylake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 6.9 (x64) or later
Red Hat Enterprise Linux 7.3 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
SUSE Linux Enterprise Server 11.4 (x64) or later
SUSE Linux Enterprise Server 12.2 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 16.04.1 LTS (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later
For Cascade Lake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 7.6 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
SUSE Linux Enterprise Server 12.3 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 6.9 (x64) or later
Red Hat Enterprise Linux 7.3 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
SUSE Linux Enterprise Server 11.4 (x64) or later
SUSE Linux Enterprise Server 12.2 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 16.04.1 LTS (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later
For Cascade Lake processors:
Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019
Red Hat Enterprise Linux 7.6 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
SUSE Linux Enterprise Server 12.3 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later
Weight
L6 system: 31.5kg
System Fans
10 x 60x60x38mm (21,700rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Operating humidity: 8-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)
Packaging Dimensions
1167 x 770 x 280 mm
Packaging Content
1 x H281-PE0
8 x CPU heatsinks
1 x Rail kit
8 x Non-Fabric CPU carrier
8 x CPU heatsinks
1 x Rail kit
8 x Non-Fabric CPU carrier
Part Numbers
Barebone: 6NH281PE0MR-00
Spare parts:
- Motherboard: 9MH81LM0NR-00
- System transfer board: 9CNBH07NR-00
- HDD back plane board: 9CBPH020NR-00
- CMC board: 9CMBH20NR-00
- Riser card board: 9CRSH012NR-00
- Tool-less rail kit: 25HB2-A86102-K0R - CPU heatsink 1: 25ST1-253206-C1R
- CPU heatsink 2: 25ST1-253207-C1R
- 7mm HDD/SSD tray: 25EK3-H28100-U0R
- Fan module: 25ST2-663821-S0S
- Power supply: 25EP0-222001-D0S
- C19 type power cord 125V/15A (US): 25CP1-018000-Q0R (in option)
- C19 type power cord 250V/16A (EU): 25CP3-01830H-Q0R (in option)
- C19 type power cord 250V/15A (US): 25CP1-018300-Q0R (in option)
Spare parts:
- Motherboard: 9MH81LM0NR-00
- System transfer board: 9CNBH07NR-00
- HDD back plane board: 9CBPH020NR-00
- CMC board: 9CMBH20NR-00
- Riser card board: 9CRSH012NR-00
- Tool-less rail kit: 25HB2-A86102-K0R - CPU heatsink 1: 25ST1-253206-C1R
- CPU heatsink 2: 25ST1-253207-C1R
- 7mm HDD/SSD tray: 25EK3-H28100-U0R
- Fan module: 25ST2-663821-S0S
- Power supply: 25EP0-222001-D0S
- C19 type power cord 125V/15A (US): 25CP1-018000-Q0R (in option)
- C19 type power cord 250V/16A (EU): 25CP3-01830H-Q0R (in option)
- C19 type power cord 250V/15A (US): 25CP1-018300-Q0R (in option)
* The entire materials provided herein are for reference only. GIGABYTE reserves the right to modify or revise the content at anytime without prior notice.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.
* Advertised performance is based on maximum theoretical interface values from respective Chipset vendors or organization who defined the interface specification. Actual performance may vary by system configuration.
* All trademarks and logos are the properties of their respective holders.
* Due to standard PC architecture, a certain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount.
SUPPORT
Driver
BIOS
Utility
Firmware
- Choose your OS
- Choose your OS
- Windows Server 2019
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Linux
Chipset
Chipset
Version
Size
Date
Intel® Chipset Driver
Version : 10.1.17861.8101
3.34 MB
2019/04/18
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Chipset Driver
Version : 10.1.18228.8176
3.12 MB
2019/12/29
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
LAN
LAN
Version
Size
Date
Intel® LAN Driver and Utility
Version : 23.5
487.48 MB
2019/04/18
OS: Windows Server 2012 R2 64bit,Linux,Windows Server 2016 64bit,Windows Server 2019
SATA RAID/AHCI
SATA RAID/AHCI
Version
Size
Date
Intel® SATA Preinstall driver
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
Version : 6.0.0.1357
6.54 MB
2019/04/19
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Rapid Storage Technology enterprise (Intel® RSTe)
Version : 6.0.0.1357
265.09 MB
2019/04/21
OS: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Utility
BIOS
Description
Version
Size
Date
1. Updated RC 0610.D02 (2020.2 IPU PV)
2. Updated microcode: SKX-H0: MB750654_02006A08, CLX-B0: MBF50656_04003003, CLX-B1: MBF50657_05003003
2. Updated microcode: SKX-H0: MB750654_02006A08, CLX-B0: MBF50656_04003003, CLX-B1: MBF50657_05003003
Version : R11
20.86 MB
2021/01/25
1. Add microcode for Processor P-8124 and P-8136
2. Add two setup item "Custom Refresh Enable" and "Custom Refresh Rate”
2. Add two setup item "Custom Refresh Enable" and "Custom Refresh Rate”
Version : R10
20.54 MB
2020/09/17
Windows and UEFI mode flash BIOS SOP
Please download BIOS update tool from AMI Website
Please download BIOS update tool from AMI Website
-
0.61 MB
2020/04/27
Warning:
Because BIOS flashing is potentially risky, if you do not encounter problems using the current version of BIOS, it is recommended that you not flash the BIOS. To flash the BIOS, do it with caution. Inadequate BIOS flashing may result in system malfunction.
What is a BETA?
BETA describes a new version that is reliable yet may not include all the features of the final product. During this phase we are previewing new features and gathering customer input to insure our product provides the best experience possible.
Because BIOS flashing is potentially risky, if you do not encounter problems using the current version of BIOS, it is recommended that you not flash the BIOS. To flash the BIOS, do it with caution. Inadequate BIOS flashing may result in system malfunction.
What is a BETA?
BETA describes a new version that is reliable yet may not include all the features of the final product. During this phase we are previewing new features and gathering customer input to insure our product provides the best experience possible.
- Choose your OS
- Choose your OS
- Windows Server 2019
- Windows Server 2016 R2 64bit
- Windows Server 2016 64bit
- Windows Server 2012 R2 64bit
- Windows Server 2012 64bit
- Windows 10 64bit
- VMware
- Ubuntu
- Linux CentOS
- Linux
Utility
Description
Version
Size
Date
GSM CLI
Version : 2.1.44
114.54 MB
2021/03/06
OS: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019
GSM Server
Version : 2.04
1147.65 MB
2020/12/04
OS: Linux,Windows Server 2016 64bit,Windows Server 2019
GSM Agent
Version : 1.02
671.51 MB
2018/09/21
OS: Linux,Windows Server 2016 64bit,Windows Server 2019
Firmware
Description
Version
Size
Date
BMC Firmware with embedded GIGABYTE Management Console
(AST2500 AMI)
1. ErP Lot9 Supported
2. Guidelines to Preserve Configuration Settings (ErP Lot9 Update)
3. Vertiv BMC EOL & Update Procedure
(AST2500 AMI)
1. ErP Lot9 Supported
2. Guidelines to Preserve Configuration Settings (ErP Lot9 Update)
3. Vertiv BMC EOL & Update Procedure
Version : 12.49.06
94.56 MB
2020/11/29
English
BMC Firmware with embedded GIGABYTE Management Console
(AST2500 AMI)
1. Vertiv BMC EOL & Update Procedure
2. Guidelines to Preserve Configuration Settings (ErP Lot9 Update)
(AST2500 AMI)
1. Vertiv BMC EOL & Update Procedure
2. Guidelines to Preserve Configuration Settings (ErP Lot9 Update)
Version : 12.40.30
84.21 MB
2020/03/08
English
Manual
Description
Version
Size
Date
User Guide - BIOS setup manual (Intel Purley platform)
Version : 1.0
19.52 MB
2017/08/17
English
Resources
Success Case
Articles
White Paper
White Paper
5G iMEC Networking Platform
[SOLUTION BRIEF] In order to upgrade their infrastructure to meet the latency and Quality of Service (QoS) requirements of 5G while reducing costs, commercial or private network operators can implement a Multi-Access Edge Computing (MEC) architecture, and utilize Network Functions Virtualization (NFV) together with general purpose servers to implement Virtual Evolved Packet Core (vEPC) technology, replacing expensive proprietary hardware and software.
Submission Successful
Success Case | June 30, 2020
Over 100,000 Pokémon Fanatics Gather to Catch ‘Em All - See How GIGABYTE’s High Density Servers Help Maintain Law & Order
Large scale events can lead to a sudden surge in crowds, creating cellular network congestion. Even if the user capacity of a cell tower user is upgraded, the network operator is still unable to cope with an abrupt increase in demand. In 2019 Industrial Technology Research Institute (ITRI) therefore designed and built a “Private Cell Mobile Command Vehicle”, which can deploy a pre-5G private cellular network to avoid the problem of commercial network traffic jams. The vehicle provides the New Taipei City Police Department with smooth, uninterrupted cellular network service, allowing the police staff to remotely monitor real time footage of large scale events and deploy police resources where needed, increasing the efficiency of providing event security and safety. GIGABYTE’s H-Series High Density Servers are also helping to support ITRI’s “Private Cell Mobile Command Vehicle” by reducing the complexity of back-end infrastructure – each server combines computing, storage and networking into a single system, allowing for resources to be centralized and shared across different applications. The servers also optimize the use of time and manpower by combining and centralizing applications to simplify management procedures.
Success Case | August 13, 2019
GIGABYTE Servers Become Part of the German Aerospace Center’s Data Center
When the German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, abbreviated as DLR) wanted to expand their data center, they searched for servers that could operate smoothly in an ambient temperature of 40°C without the need for air conditioning. GIGABYTE’s server team provided a solution from its High Density Server product line that combined computing, storage, and connectivity in a single system. The High Density Servers are equipped with liquid-cooling technology to run without a hitch in high-temperature environments, enabling the data center to efficiently process an enormous amount of space-related research data in the limited space available.
Tech Guide | March 16, 2021
How to Pick a Cooling Solution for Your Servers? A Tech Guide by GIGABYTE
As CPUs and GPUs continue to advance, they consume more power and generate more heat. It is vital to keep temperature control in mind when purchasing servers. A good cooling solution keeps things running smoothly without hiking up the energy bill or requiring persistent maintenance. GIGABYTE Technology, an industry leader in high-performance servers, presents this tech guide to help you choose a suitable cooling solution. We analyze three popular options—air, liquid, immersion—and demonstrate what GIGABYTE can do for you.
5G | November 04, 2019
Seize New Business Opportunities with Practical Applications of 5G
Recently, 5G communications technology has been frequently talked about in relation to various major industries – it even seems that in order to keep up with technology trends, everything should be connected with 5G! When discussing 5G however, key features such as high bandwidth, low latency and high connection density must definitely be mentioned. As the coming of 5G will revolutionize our future lives, let’s understand more clearly about 5G directly from some real-world examples! And what key role does GIGABYTE play in this next generation communications technology?
5G | July 22, 2019
What is 5G? An Introduction to 5G Networks and Applications
5G communications has been a very hot topic in recent years. Due to some of the key attributes such as faster data transfer rate, low latency and high connectivity, people can start to develop applications including industry 4.0, autonomous cars, and build a smart city etc. However, until the day comes when 5G is widely applied in our everyday technologies, people still wonder what exactly is 5G? How is it different from 4G? Despite a proclaimed faster data transfer rate, how will it impact the next tech evolution?
Video


Video | April 12, 2021
Compact GPU Powerhouse: 2U GIGABYTE Server with 8 x GPUs
Designing a 2U server that can accommodate up to 8 dual slot GPUs was a challenge, and the G292-Z40 delivers without sacrificing performance using isolated ...


Video | April 08, 2021
List of New GIGABYTE Products for 3rd Gen Intel Xeon Scalable Processors
Intel has made incredible advances with its 40+ SKUs of 3rd Gen Intel Xeon Scalable processors. Higher core count, PCIe 4.0 support with up to 64 lanes per socket, increase in memory bandwidth and total system memory per socket, as well as AI and security boosts have been added while maintaining a competitive price to make these servers an excellent choice for upcoming new sever builds or legacy servers looking to upgrade from prior generations.


Video | March 30, 2021
60秒小科普:看懂什麼是液體冷卻 Liquid Cooling
什麼是液體冷卻Liquid Cooling? 液冷技術(Liquid Cooling)顧名思義就是以液體作為熱量傳導機制的散熱方式,市場上常見的有沉浸式液冷 ...


Video | March 29, 2021
What is it? Liquid Cooling in 60 seconds
What is Liquid Cooling? As the name suggests, liquid cooling technology uses liquid as a heat transfer mechanism. Two common liquid ...


Video | March 25, 2021
What is it? Data Center in 60 Seconds
What is a data center? A data center is a facility that an organization uses for housing their IT equipment, including servers, storage, ...


Video | March 25, 2021
60秒小科普:看懂什麼是 Data Center 資料中心
數據中心是什麼? 數據中心(Data Center)是容納組織中IT設備的設施,包括伺服器、儲存、網路設備(如交換機、路由器和防火牆),以及組織和 ...


Video | March 24, 2021
How to upgrade to Milan TW
如果你手上有相容AMD EPYC 7002 CPU的技嘉伺服器,只要透過更新BIOS就可以輕鬆升級到第三代EPYC,請參考技嘉官網針對第三代EPYC的伺服器支援清單( ...


Video | March 24, 2021
How to upgrade your system to AMD EPYC 3rd Gen Processors?
If you have a GIGABYTE server designed for AMD EPYC 7002 Series processors, you can painlessly upgrade your system with a BIOS update. On GIGABYTE's ...


Video | March 22, 2021
A Place for All Enterprise Things
Find Your Enterprise Solutions at https://bit.ly/2PfpQ6q This new enterprise homepage will provide easier access for IT professionals and businesses to find ...


Video | March 18, 2021
Ready for our new program "GIGABYTE Tech Tune-In"
Tune in to GIGABYTE'S EXCLUSIVE 'CHANNEL' for webinars, insights, and product solutions on topics of technologies that are transforming the world today.


Video | March 17, 2021
技嘉搭載新一代AMD EPYC系列伺服器,第一波全線公開
技嘉科技首波發表搭載新一代AMD EPYC™ 7003 系列處理器的新伺服器產品如下。整體而言,此新一代搭載AMD EPYC™ 7003 系列處理器的伺服器在單一核心 ...


Video | March 16, 2021
GIGABYTE Launches 1st Wave of Servers for AMD EPYC™ 7003 Series Processors
GIGABYTE servers have been tested and are ready for AMD EPYC 7003 Series processors. The following is a list of models available in the 1st wave ready for ...


Video | March 15, 2021
GIGABYTE Servers and 3rd generation AMD EPYC™ Processors
GIGABYTE announced over 40 servers and server motherboards ready for the new AMD EPYC™ 7003 Series processors. These new servers will target modern ...
News
News | December 04, 2020
Showcasing AMD-Based Solutions and Successes at Annual GIGABYTE-Weikeng Partner Conference
EPYC™ Series Processers Offer Value and Performance, Bringing HPC to Particle Physics, Space Exploration, and Climate Change Studies
News | February 24, 2020
Unlimit Your Possibilities with GIGABYTE Servers Ready for the Latest 2nd Gen. Intel® Xeon® Scalable Processors
Security & Technical Advisory
Others
Back to H281-PE0

Compare
Remove All
You may only add up to 5 items for comparison at one time.
Close
Contact our sales team
Please contact us if you would like to know more about our products. For services and support, please visit eSupport.
* Inquiries:
* Are you a system integrator?
To ensure our emails be delivered to your inbox, please avoid using free-to-use email services such as Yahoo, Gmail, Hotmail etc.
0 / 1000
Submitted Successfully