G591-HS0
(rev. 100)

Discontinued

HPC Server - 5U 32 x PCIe GPU Server
  • Supports 5G network infrastructure
  • Up to 32 x PCIe low profile GPU slots
  • Up to 8 x PCIe low profile high speed LAN connectivity slots
  • 2nd Gen. Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
  • 6-Channel RDIMM/LRDIMM DDR4, 24 x DIMMs
  • Supports Intel® Optane™ DC Persistent Memory
  • 2 x GbE LAN ports (Intel® I350-AM2)
  • 4 x 2.5" NVMe, 6 x 2.5" SATA/SAS hot-swappable HDD/SSD bays
  • 1 x low profile PCIe Gen3 expansion slots in front side
  • 1 x OCP 2.0 Gen3 x8 mezzanine slot
  • Aspeed® AST2500 remote management controller
  • 4 x 80 PLUS Platinum 2200W redundant PSU
* Todos los materiales aquí provistos son sólo para referencia. GIGABYTE se reserva el derecho de modificar o revisar el contenido a cualquier hora sin aviso alguno.
* Todas las marcas y logos son propiedad de sus propios dueños.
* Debido a la arquitectura estándar de la PC, cierta cantidad de memoria es reservada para uso del sistema y actualmente la memoria disponible es menor a la mencionada.

SPECIFICATIONS

Dimensions (WxHxD, mm)
5U
447 x 219.6 x 900
Motherboard
MG61-G40
CPU
2nd Generation Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors
Intel® Xeon® Platinum Processor, Intel® Xeon®Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor

System TDP up to 205W

NOTE: If only 1 CPU is installed, some PCIe and memory functions might be unavailable
Socket
2 x LGA 3647
Socket P
Chipset
Intel® C621 Chipset
Memory
24 x DIMM slots
DDR4 memory supported only
6-channel memory architecture
RDIMM modules up to 64GB supported
LRDIMM modules up to 128GB supported
Supports Intel® Optane™ DC Persistent Memory (DCPMM)
1.2V modules: 2933/2666/2400/2133 MHz

Maximum verified DCPMM configuration:

* Ambient temperature 35°C
* 2nd Generation Intel® Xeon® Scalable processor 205W (Max.)
* DCPMM 256GB x12 pcs

DCPMM installation locations:
DIMM_P0_(A1, B1, C1)
DIMM_P0_(D1, E1, F1)
DIMM_P1_(G1, H1, I1)
DIMM_P1_(J1, K1, L1)

NOTE:
1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only
2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only
3. The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C
4. To enquire about installing a greater number of DCPMM, please consult with your GIGABYTE technical or sales representative
LAN
2 x 1Gb/s BASE-T LAN ports (Intel® I350-AM2)
1 x 10/100/1000 management LAN
Video
Integrated in Aspeed® AST2500
2D Video Graphic Adapter with PCIe bus interface
1920x1200@60Hz 32bpp, DDR4 SDRAM
Storage
4 x 2.5" NVMe, 6 x 2.5" SATA/SAS hot-swappable HDD/SSD bays

SAS card is required to enable SAS devices support
SATA
Supported
SAS
N/A
RAID
For SATA drives:
Intel® SATA RAID 0/1/10/5

For U.2 drives:
Intel® Virtual RAID On CPU (VROC) RAID 0, 1, 10, 5

Note: VROC module is compatible for Intel®SSD only
Peripheral Drives
N/A
Expansion Slots
32 x PCIe x16 low profile half-lengh slots (Gen3 x16 bus) for GPUs
8 x PCIe x16 low profile half-lengh slots (Gen3 x16 bus) for LAN connectivity

1 x PCIe low profile half-lengh slots (Gen3 x8 bus) for add-on cards ( Front side)

1 x OCP 2.0 mezzanine slot ( Rear side)
- PCIe Gen3 x8
- Type1, P1, P2, P3, P4, K2, K3
Internal I/O
1 x TPM header
1 x VROC connector
1 x Front VGA header
1 x Serial header
Front I/O
2 x USB 3.0
1 x VGA
2 x RJ45
1 x MLAN (Primary port)
1 x Power button with LED
1 x ID button with LED
1 x Reset button
1 x System status LED
1 x HDD access LED
2 x LAN activity LEDs
Rear I/O
1 x MLAN (Reserved, enabled by jumper switch)
Backplane Board
Speed and bandwidth: SATA 6Gb/s, SAS 12Gb/s per port
TPM
1 x TPM header with SPI interface
Optional TPM2.0 kit: CTM010
Power Supply
4 x 2200W redundant PSUs
80 PLUS Platinum

AC Input:
- 100-127V~/ 14A, 47-63Hz
- 200-240V~/ 12.6A, 47-63Hz

DC Input:
- 240Vdc/ 12.6A

DC Output:
- Max 1200W/ 100-127V~
+ 12.12V/ 95.6A
+ 12Vsb/ 3.5A
- Max 2200W/ 200-240V~
+ 12.12V/ 178.1A
+ 12Vsb/ 3.5A

NOTE:
* The system power supply requires C19 type power cord
System Management
Aspeed® AST2500 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface

  • Dashboard
  • JAVA Based Serial Over LAN
  • HTML5 KVM
  • Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
  • Sensor Reading History Data
  • FRU Information
  • SEL Log in Linear Storage / Circular Storage Policy
  • Hardware Inventory
  • Fan Profile
  • System Firewall
  • Power Consumption
  • Power Control
  • LDAP / AD / RADIUS Support
  • Backup & Restore Configuration
  • Remote BIOS/BMC/CPLD Update
  • Event Log Filter
  • User Management
  • Media Redirection Settings
  • PAM Order Settings
  • SSL Settings
  • SMTP Settings
OS Compatibility
For Skylake processors:

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019

Red Hat Enterprise Linux 6.9 (x64) or later
Red Hat Enterprise Linux 7.3 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later

SUSE Linux Enterprise Server 11 SP4 (x64) or later
SUSE Linux Enterprise Server 12 SP2 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later

Ubuntu 16.04.1 LTS (x64) or later
Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 or later
VMware ESXi 6.7 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.4.0 or later
Citrix Hypervisor 8.0.0 or later

For Cascade Lake processors:

Windows Server 2012 R2 with Update
Windows Server 2016
Windows Server 2019

Red Hat Enterprise Linux 7.6 (x64) or later
Red Hat Enterprise Linux 8.0 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later

SUSE Linux Enterprise Server 12 SP3 (x64) or later
SUSE Linux Enterprise Server 15 (x64) or later

Ubuntu 18.04 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later

VMware ESXi 6.0 Update3 or later
VMware ESXi 6.5 Update2 or later
VMware ESXi 6.7 Update1 or later
VMware ESXi 7.0 or later
VMware ESXi 8.0 or later

Citrix Xenserver 7.1.0 CU2 or later
Citrix Xenserver 7.5.0 or later
Citrix Hypervisor 8.0.0 or later
System Fans
10 x 60x60x76mm (21,700rpm)
Operating Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8%-80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20%-95% (non-condensing)

NOTE: Please contact Technical Support for more information about optimized GPU system operating temperature
Weight
Net Weight: 50.18 kg
Gross Weight: 60.5 kg
Packaging Content
1 x G591-HS0
2 x CPU heatsinks
1 x Rail kit
1 x VROC module
2 x Non-Fabric CPU carrier
Part Numbers
- Barebone with rail kit: 6NG591HS0MR-00
- Motherboard: 9MG61G40NR-00
- VROC module: 25FD0-R181N0-10R
- Rail kit: 25HB2-A96100-K0R
- CPU heatsink: 25ST1-323206-A0R
- Fan module: 25ST2-667620-S0R
- Power supply: 25EP0-222003-D0S
- C19 type power cord 125V/15A (US): 25CP1-018000-Q0R (optional)
- C19 type power cord 250V/16A (EU): 25CP3-01830H-Q0R (optional)
- C19 type power cord 250V/15A (US): 25CP1-018300-Q0R (optional)
* Todos los materiales aquí provistos son solo para referencia. GIGABYTE se reserva el derecho de modificar o revisar el contenido a cualquier hora sin aviso alguno.
* Todas las marcas y logos son propiedad de sus propios dueños.
* Debido a la arquitectura estándar de la PC, cierta cantidad de memoria es reservada para uso del sistema y actualmente la memoria disponible es menor a la mencionada.

SUPPORT

  • All
  • All
  • Windows Server 2019
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Linux
LAN
LAN
Versión
Tamaño
Fecha
SATA RAID/AHCI
SATA RAID/AHCI
Versión
Tamaño
Fecha
Intel® SATA Preinstall driver
(For AHCI / RAID Mode)
Note: Windows setup to read from USB devices
Version : 6.0.0.1357
6.54 MB
Apr 19, 2019
S.O.: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Intel® Rapid Storage Technology enterprise (Intel® RSTe)
Version : 6.0.0.1357
265.09 MB
Apr 21, 2019
S.O.: Windows Server 2012 R2 64bit,Windows Server 2016 64bit,Windows Server 2019
Warning:
Because BIOS flashing is potentially risky, if you do not encounter problems using the current version of BIOS, it is recommended that you not flash the BIOS. To flash the BIOS, do it with caution. Inadequate BIOS flashing may result in system malfunction.

What is a BETA?
BETA describes a new version that is reliable yet may not include all the features of the final product. During this phase we are previewing new features and gathering customer input to insure our product provides the best experience possible.

  • All
  • All
  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016 R2 64bit
  • Windows Server 2016 64bit
  • Windows Server 2012 R2 64bit
  • Windows Server 2012 64bit
  • Windows 10 64bit
  • VMware
  • Ubuntu
  • Linux CentOS
  • Linux
Utilidad
Descripción
Versión
Tamaño
Fecha
GSM CLI
Version : 2.1.72
147.86 MB
Mar 05, 2024
S.O.: Windows Server 2012 64bit,Windows Server 2012 R2 64bit,Linux CentOS,Windows 10 64bit,Ubuntu,Windows Server 2016 R2 64bit,Windows Server 2019,Windows Server 2022
Manual
Descripción
Versión
Tamaño
Fecha

RESOURCES

Security & Technical Advisory
Back to G591-HS0
{{ selectedProductCount }}
Compare
  • {{ selectedProducts[index].modelName }}
Clear All
Regresar
You may only add up to 4 items for comparison at one time.