TDP | 熱設計功耗

  • What is it?
    Thermal design power, also known as thermal design point, is defined as the theoretical maximum amount of heat generated by a CPU or GPU that its cooling system is designed to dissipate. It is usually measured in watts (W) or kilowatts (KW), but it does not represent the actual amount of electricity that the processor consumes; rather, it is the power consumption ceiling that should not be exceeded, if the user wishes to avoid overheating. Most processors can be made to consume more power than its intended TDP—overclocking enthusiasts often do so—but processor throttling, also known as automatic underclocking, may kick in to make sure the power draw does not exceed the TDP.

    In a stable, enterprise-grade server room or data center, the TDP roughly equates to the computing equipment's power consumption, since the servers are usually operating at or close to maximum capacity. How to improve thermal management to accommodate a higher TDP has become an area of interest in the era of high performance computing (HPC), as IT experts try to get more computing power out of their processors.

  • Why do you need it?
    Since TDP represents the theoretical heat generation ceiling—and by extension, the theoretical power consumption ceiling—of a piece of computing equipment, a higher TDP can be seen as representative of more computing power and better processor performance. The higher amount of heat will need to be effectively dissipated to support the higher TDP. This can be achieved by lowering the ambient temperature (also known as the baseline temperature or "set point") in an air-cooled data center, or by adopting more innovative data center cooling solutions, such as liquid cooling or immersion cooling.

  • How is GIGABYTE helpful?
    GIGABYTE Technology is well-versed in server cooling and offers server solutions that are optimized for all the mainstream cooling methods, including air cooling, liquid cooling, single-phase immersion cooling, and two-phase immersion cooling. Efficient cooling can protect the servers from exceeding their intended TDP, leading to greater reliability and higher availability. In the case of liquid cooling or immersion cooling, a higher ambient temperature may even be acceptable due to the superb cooling efficacy of these methods. This will result in not only lower power consumption and a more eco-friendly carbon footprint, it may also lead to better chip performance.

    Air-cooled servers: GIGABYTE's air-cooled servers come with a proprietary airflow-friendly hardware design, which means the direction of the airflow within the chassis has been evaluated with simulation software, and then fine-tuned to optimize ventilation. Powerful fans, high-performance heat sinks, and special air ducts or shrouds are installed to further improve the airflow. Other creative and unique modifications, which may differ between the various product lines, enable GIGABYTE to lead the industry in thermal management and allow for higher TDPs that unlock the full extent of the processors' computing power.

    Liquid-cooled servers: Liquid cooling, also known as direct liquid cooling (DLC) or direct-to-chip (D2C) liquid cooling, uses sealed tubes (called cooling loops) filled with coolant to disperse heat. GIGABYTE has teamed up with a leading cooling solutions provider to provide high-density, factory-installed liquid-cooled servers. For instance, GIGABYTE has deployed a liquid-cooled HPC cluster in the data center of the German National Aerospace Center (DLR), so it can utilize superb processing power in the fields of aviation, aerospace, and transportation, without increasing the carbon footprint.

    Single-phase immersion cooling: The apex of data center cooling is immersion cooling. The single-phase variant soaks the servers in a bath of dielectric, nonconductive coolant, and then cycle the warm coolant to a coolant distribution unit (CDU) to remove the heat. Not only does this reduce the data center's power consumption and carbon footprint, it is possible to have a higher ambient temperature and a higher TDP, which will unleash more computing power. GIGABYTE has provided a single-phase immersion cooling solution for Japan's telco giant KDDI.

    Two-phase immersion cooling: The two-phase variant has the coolant undergoing a recurring cycle of vaporization and condensation inside a sealed tank. This process transfers the thermal energy from the server to the liquid coolant, and then to the rising vapors that are cooled by the condenser at the top of the tank. GIGABYTE has built a “two-phase immersion cooling solution” for the IC foundry giant that leads the world in advanced process technology; it has helped the industry leader achieve PUE below 1.08 and an increase of more than 10% in chip performance.

  • WE RECOMMEND
    RELATED ARTICLES
    如何挑選您的AI伺服器?(下)記憶體、儲存裝置和其他元件

    Tech Guide

    如何挑選您的AI伺服器?(下)記憶體、儲存裝置和其他元件

    人工智慧盛行的當下,各種組織積極導入「AI伺服器」。技嘉科技最新發表的《科技指南》:「如何挑選您的AI伺服器?」,文章下半篇將介紹CPU和GPU以外的六個關鍵零組件。挑選合適元件可讓AI伺服器的性能達到顛峰,勝任人工智慧的相關工作。
    帶您快速跟上人工智慧AI趨勢的十大問答

    AI & AIoT

    帶您快速跟上人工智慧AI趨勢的十大問答

    大家都在談人工智慧(AI),您是否也希望擁有基本的知識,參與這個話題的討論?別擔心,技嘉科技為您準備了介紹AI趨勢的十大問答,讓您能快速理解人工智慧的概念!
    如何挑選適當的伺服器冷卻方案? 技嘉科技《科技指南》系列文章

    Tech Guide

    如何挑選適當的伺服器冷卻方案? 技嘉科技《科技指南》系列文章

    隨著科技進步,新一代的處理器使用更多電力、產出更多熱能。選購伺服器時,應當留意溫控問題,好的冷卻方案可確保伺服器正常運作,且不至於太耗電、或是需要頻繁的維修。 技嘉科技是高性能伺服器的領導品牌,本篇《科技指南》針對市面上廣泛使用的三種散熱方法(氣冷式、液冷式和浸沒式)逐一說明,並介紹技嘉的相關產品,協助您挑選最適合的解決方案。
    技嘉藉由單相浸沒式液冷技術 助力日本電信龍頭KDDI開發新世代資料中心

    Success Case

    技嘉藉由單相浸沒式液冷技術 助力日本電信龍頭KDDI開發新世代資料中心

    日本電信業界龍頭KDDI,因應新世代需求,積極研發對環境友善、便於移動的「貨櫃型浸沒式液冷小型資料中心」,此資料中心採用「單相浸沒式液冷」技術,可減少43%的總耗能,並將PUE改善至1.07以下。技嘉科技於浸沒式液冷解決方案擁有豐富的研發與部署經驗,提供機架式伺服器R282-Z93與R182-Z91,肩負資料中心管理節點和GPU運算節點的任務。技嘉伺服器的強項,是在有限空間內部署高密度、高擴充性的處理器配置,其優異的機構設計,能發揮第三代AMD EPYC™中央處理器及NVIDIA® GPU加速器的最大運算力。協助客戶開發「浸沒式液冷資料中心」,亦是技嘉深耕環境、社會與治理的ESG長期努力目標,技嘉攜手產業夥伴和客戶,積極實踐「創新科技,美化人生」的企業使命。
    規劃資料中心冷卻方案時 不可不知的5個關鍵知識

    Cooling

    規劃資料中心冷卻方案時 不可不知的5個關鍵知識

    三個簡單步驟,輕鬆挑選伺服器冷卻方案

    Cooling

    三個簡單步驟,輕鬆挑選伺服器冷卻方案

    兼顧伺服器效能與企業永續發展的最佳解方

    Cooling

    兼顧伺服器效能與企業永續發展的最佳解方

    解碼綠色運算與低碳轉型的首選 - 資料中心冷卻方案

    Tech Guide

    解碼綠色運算與低碳轉型的首選 - 資料中心冷卻方案